Aircon Installation

Latest Promotion

  • For replacement only
  • Free survey site & quotation
  • All inverter system
  • Prices quoted are inclusive of GST

DAIKIN

System 2 (9K+9K) $1,988,00
System 3 (9K+9K+12K) $2,688,00

TOSHIBA

System 2 (9K+9K) $2,099,00
System 3 (9K+9K+12K) $2,599,00

MITSUBISHI

System 2 (9K+9K) $1,988,00
System 3 (9K+9K+12K) $2,688,00

TOSHIBA

System 2 (9K+9K) $1,888,00
System 3 (9K+9K+12K) $2,488,00

MITSUBISHI HEAVY INDUSTRIES

System 2 (9K+9K) $1,988,00
System 3 (9K+9K+12K) $2,688,00

Aircon Installation Materials

1. Stainless steel bracket must be used to support the air-conditioning units in one of the standard methods stipulated in the Building Control Regulations.

2. Manufactured from an extra High Impact grade, Fire Resistant rated and complies with the Singapore Standard.

3. Installation of air-conditioner (casement/ window unit/ split type) using new 15 amps power point or new 20 amps isolator

4. Insulation: the material used to cover the copper pipe, usually rubber foam, which helps to absorb water droplets formed due to condensation on the copper pipes when the air-conditioner is operating. ⅜ inches is usually recommended for the piping in trunking while ½ inches is preferred for piping that will be hidden by false ceilings or concealed in walls.

5. Grade (or gauge): thickness of the copper pipe, generally a thicker copper pipe is able to withstand a higher operating pressure. The grade varies from G25 (0.51mm) to G21 (thickest). For HDB owners, the G23 (0.61mm) is usually recommended. If you have concealed piping, then G22 (0.71mm) is a better option. Another thing you should take note is the bending of the copper piping. To lower the odds of condensation or poor refrigerant flow (which will make the air-conditioner less cold), make sure that the piping is bent with a proper pipe bender (thus ensuring a pipe bent of about 90 degrees).

6. PVC drainage pipe: Installers generally use one of 2 sizes available in the market: 13mm and 16mm (referring to the pipe’s internal diameter). Using a bigger size will mean that the air-conditioner is able to drain water faster and slow down the possibility of leakage.

7. Wiring: 2 types are usually used to connect the air-conditioner to its power source as well as connect the indoor units to the outdoor one: 3C70 (3 wire cords, each with 70 copper stands) and 3C40 (3 wire cords, each with 40 copper strands).